Problem...
Are you experiencing an issue with the following...
Your scale show strange figures and just behaves naugthy?
Solution...
Try solving it by doing the following...
Basics:
Place the scale on a flat, level surface. Press the ON/OFF key to switch on the scale. Wait until "0.0" is displayed, then you are ready to weigh. Place object(s) on the platform. Wait a few seconds for the display to stabilise before taking a weight reading. You can switch between the weighing units by pressing the MODE key. Only operate the scale on a stable, vibration-free surface.
Calibration Instructions:
1. Turn on the scale by pressing the [ON/OFF] key and wait until 0.0g is displayed.
2. Tap the [CAL] key, then CAL is displayed.
3. Press the [CAL] key again. The LCD will display the required calibration weight.
4. Place the required calibration weight on the centre of the platform. The LCD will display PASS and return to the normal weighing mode.
5. Remove the calibration weight and press the [ON/OFF] key to turn off the scale. Calibration is complete.